The set values of the high and low pH alarms are factory pre-set to 6.7 and 7.9. These
values can be modified through the alarm mode (see Alarm mode [
CAUTION
pH too high or too low!
Skin irritation
ü Ensure that:
ü the cylinder has been removed from the pH probe (see Installation of probes
[
Page 42])
ü the pH probe was calibrated less than 6  months ago (see Calibration mode
[
Page 76])
ü pH probe is not clogged (see Cleaning the pH or RedOx probe [
• manual regulation: put the product "pH-" or "pH+" according to the pH drift.
• automatic regulation: check the proper functioning of the equipment.
If the pH value is Hi or Lo, check that an air bubble at the bottom of the pH probe does not distort
the measurement. Shake the device (like a mercury thermometer) so that, by centrifugal force,
any air bubble rises.
5.2.4

Conductivity Trend

1.
Conductivity trend
(updated every 2 hours)
2.
Conductivity has reached
alarm value
Ref. SB-CU-IMP-058EBA / A - 11.05.2023
Installation and Operation Guide Version E-Box INTELLIPOOL - Programming
ACID
1
conductivity rises
conductivity is stable
conductivity decreases
value
(factory pre-set at 50  μS, can be changed on the alarm
menu, see Alarm mode [
value
(factory pre-set at 1200 μS, can be changed on the alarm
menu, see Alarm mode [
IDEAL
2
3
4
5
the conductivity has reached the maximum alarm
the conductivity has reached the minimum alarm
Page 72]).
BASIC
Page 87])
Page 72])
Page 72])