1-2
Connection of the Heat Pump Power Supply (230 V)
3-4
Variable Speed Pump Power Supply Connection (230 V)
5-6
Pool Automatic Shutter Power Supply Connection (230 V)
7-8
Connection of the Metering Pump Power Supply for pH control (230 V)
9-10
Connection of the power supply for the metering pump for chlorine regulation or of the
power supply to the electrolyser (230 V)
11-12
AUX 3 Possibility of connecting an additional pump (blower, cascade, blower) under
230 V 12 A max. by setting the function on the website – Operates parallel to the
contacts 25-26
13-14
AUX4 Possibility of connecting an additional accessory under 230 V 10 A max. by setting
the function on the website – Works parallel to the contacts 27-28
15-16
AUX 5 Possibility of connecting an additional accessory under 230 V 10 A max. by setting
the function on the website – Operates parallel to the dry contacts 29-30
In order to operate the outputs correctly, it is necessary to configure them on the website.
These settings may be partly carried out on the interface of the Intellipool, through the related
menus.
4.8.2.2
Terminal block 2: Low voltage connection (12-24 V)
17-18
AUX 1 Possibility of connecting an additional accessory (robot blower) through a dry
contact under 230 V 8 A max. by setting the function on the website (AUX1 also controls
the "Robot" socket in 230 V on the side of the E-Box)
19-20
Dry contact connection for controlling an electrolyser through its flow-switch
21-22
Control of lighting by dry contact (same parameters as with the output of the 8 Amps
Max/230 V lighting output)
23-24
Dry contact for controlling the heating of the pool (through the heat pump flow switch or
the "Remote or Remote Control" contacts of the heat pump)
25-26
Control by the AUX 3 dry contact (same parameters as with the AUX 3 output in 230 V
15/16) 8 Amps Max under 230 V
27-28
Control by the AUX 4 output dry contact (same parameters as with the AUX 4 output in
230 V 13/14) 8 Amps Max/230 V
29-30
Control by the AUX 5 output dry contact (same parameters as with the AUX 5 output in
230 V 15/16) 8 Amps Max/230 V
31-32
"Input 1" information input on the 4X Extension Unit module
33-34
"Input 2" information input on the 4X Extension Unit module
35-36
"Input 3" information input on the 4X Extension Unit module
37-38
"Input 4" information input on the 4X Extension Unit module
39-40
Information input "Alarm 1" on the 4X Extension Unit module
41-42
Information input "Alarm 2" on the 4X Extension Unit module
Ref. SB-CU-IMP-058EBA / A - 11.05.2023