2. In the menu "Pool Properties > Menu Installation 4X Extension", see Menu installation 4X
Extension [
Page 47], select the output AUX  2 "Filling" and customise the name if
necessary.
3. Connect the filling solenoid valve (24 V) to terminal blocks 45-46.
4. Connect the level sensor to the input IN 1 (or 2 or 3 or 4) and then, through the installation
menu, select the "water level NO" input.
PENTAIR IntelliFlo VSF
Info
Set the appropriate speeds that is, Speed 1 (Frost Free), Speed 2 (Eco), Speed 3 (Normal)
and Speed 4 (Max), through the app in the "Intelliflo" tab.
Not supplied: the control cable.
IntelliFlo PENTAIR Speed Adjustment
• Frost free: Outlet used to trigger filtration for a water temperature < +3°C (modifiable).
• Eco Speed: Speed used when no preselected event (see relevant menu) is active.
• Normal speed: Speed used for the purposes of a preselected event (see relevant menu).
• Maximum speed: Speed used for backwashing or "shock" treatment (24  h of filtration and
electrolyser).
Phase/Neutral power supply in the E-Box
Terminals 3 and 4
The Earth on the dedicated terminal block
Ref. SB-CU-IMP-058EBA / A - 11.05.2023
Installation and Operation Guide Version E-Box INTELLIPOOL - Installation
IntelliFlo control
Dedicated terminal
block 47 (+)/48 (-)