12.3.
Valve use
Application:
Use:
Shut-off tightness:
13.1.
Installation position
Preferred installation position:
If the installation position is horizontal, increased wear and tear should be expected depending
on the operating conditions.
13.2.
Valve connections
Connections:
For welding instructions, refer to the "Welding and Mounting Instructions" chapter.
13.3.
Installation details for disk type non-return valves
Disk type non-return valve as per the assembly instructions.
Weld or mount the disk type non-return valve into the pipeline.
Welding instruction
Assembly instructions
For assembly instructions, refer to the "Disassembly - Assembly" chapter.
0
20 / 34
Copy of the original operating instructions
BAA RV Solid
Type: P740, P741, P745, P750 and P760
DN 010 – 150, OD 0.50" – 6.00", ISO 008 – 125
disk type non-return valve
hygienic processes
10 bar (145 psi) max.
Information/notice
If the column of water is less than 2 m in height (0.2 bar pressure), this may result in a
slight leak from the seal seat of the valve.
Please refer to the "Disassembly - Assembly" chapter for details of how to carefully
mount the O-ring.
13.
Valve connection piping
vertical
Information/notice
-
Welding end
Detachable connection required for maintenance
-
Threaded connection
-
Clamp connection
-
Small-flange connection
Information/notice
Dismantle the seals before welding.
Shrink-wrap valve body free from tension and distortions.
Welding work must only be carried out by qualified skilled personnel (DIN EN ISO 9606-
1 W8).
No foreign matter must remain in the pipeline when the valves are assembled.
Operating Instructions
Disk type non-return valves
RV Solid series
en