Sign In
Upload
Manuals
Brands
Pentair Manuals
Control Unit
FLECK 3150 NXT
Pentair FLECK 3150 NXT Controller Manuals
Manuals and User Guides for Pentair FLECK 3150 NXT Controller. We have
3
Pentair FLECK 3150 NXT Controller manuals available for free PDF download: Installer Manual
Pentair FLECK 3150 NXT Installer Manual (122 pages)
Brand:
Pentair
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
2
Generalities
7
Scope of the Documentation
7
Release Management
7
Manufacturer Identifier, Product
7
Intended Use
7
Abbreviations Used
8
Norms
8
Applicable Norms
8
Available Certificates
8
Procedure for Technical Support
9
Copyright
9
Limitation of Liability
9
Scan & Service Application
10
Safety
11
Safety Pictograms Definition
11
Serial Label Location
11
Hazards
11
Personnel
12
Material
12
Hygiene and Sanitization
12
Sanitary Issues
12
Hygiene Measures
12
Description
13
Technical Specifications
13
Performance Flow Rate Characteristics
15
Outline Drawing
16
Components Description and Location
17
System Regeneration Cycle
18
DF Regeneration Cycle (5-Cycles Operation)
18
UF Regeneration Cycle (5-Cycles Operation)
20
Filter Cycle (3-Cycles Operation)
22
Injector Block Position for DF and UF Configurations
23
System Sizing
24
Recommendations
24
Injector/Dlfc/Blfc-Valve Configuration
24
Sizing a Softener (Single Unit)
24
Parameters to be Considered
24
Determining the Required Volume of Resin
25
Resin Exchange Capacity and Capacity of the Unit
26
Valve Configuration
28
Cycle Time Calculation
29
Salt Amount Definition
31
1800 Injector Flow Rates
32
Installation
35
Warnings
35
Safety Notices for Installation
35
Installation Environment
35
General
35
Water
36
Electrical
36
Mechanical
36
Integration Constraints
37
Valve Connection to Piping
37
Top-Mounted Valve Installation
38
Side-Mounted Valve Installation
39
Block Diagram and Configuration Example
40
System Types
41
Single Valve (System #4)
42
Multiple Valves with Lockout (System #5)
42
Multiple Valves with Consecutive Regenerations (System #6)
43
Duplex Alternating (System #7)
43
Multiple Valves, Alternating (System #9)
44
Multiple Valves, Demand (System #14)
44
Valve Connection to Piping
48
Electrical Connections
49
Connections for Multiple Valves
50
Bypassing
51
Drain Line Connection
52
Overflow Line Connection
53
Brine Line Connection
53
Programming
54
Display
54
During Service
54
Commands
54
Setting the Time of the Day
55
Basic Programming
55
Language Setting
55
Inlet Water Hardness
56
Regeneration Days Override
56
Regeneration Start Time
56
Master Programming Mode
57
Master Programming Mode Chart
57
Entering Master Programming Mode
60
Language Setting
60
System Type
61
Valve Address in the System
61
System Size
62
Regeneration Type
62
Valve Type
63
Regeneration Flow
63
Remote Started Regeneration
64
Display Format
64
System Capacity
65
Safety Coefficient
65
Inlet Water Hardness
65
Trip Points Setting
65
Regeneration Days Override
67
Regeneration Start Time
67
Programming Regeneration Cycle Times
67
Auxiliary Relay / Chemical Pump
68
Flow Meter Selection
70
Parameters Saving
71
Diagnostic
71
Commands
71
Current Flow Rate
71
Peak Flow Rate
71
Totalizer
72
Hours between Last Two Regenerations
72
Hours Since Last Regeneration
72
Volume Remaining
73
Valve Position
73
Software Version
73
Resetting the Controller
74
Partial Reset
74
Hard Reset
74
Commissioning
75
Water Filling, Draining and Waterproofness Inspection
75
Activating a Single Valve System (System #4)
75
Activating a Multiple Valves System
76
Sanitization
76
Disinfection of Water Softeners
76
Sodium or Calcium Hypochlorite
76
Electro Chlorination
77
Operation
78
Display
78
During Service
78
During Regeneration
78
LED Status
78
Recommendations
79
Manual Regeneration
79
Manual Delayed Regeneration
79
Immediate Regeneration
79
To Advance Regeneration Cycles
79
Operation During a Power Failure
79
Maintenance
80
Recommendations
80
Use Original Spare Parts
80
Use Original Approved Lubricants
80
Maintenance Instructions
80
Cleaning and Maintenance
80
First Steps
80
Motor Replacement
81
Power Head, Piston And/Or Seal and Spacer Kit Disassembly
82
Replacement
82
Injector and BLFC Cleaning
84
Cams Replacement
86
Micro-Switches Replacement
88
Valve on Tank Assembly
89
Troubleshooting
90
Error Detection
90
Programming Error
92
Examples of Error Displayed
93
Spare Parts and Options
94
Valve Parts List
94
Power Head 3150 Parts List
96
Injector Parts List
98
Safety Brine Valves List
100
Air Checks List
100
Distribution Systems Parts List
101
Thread 4", Tank 21" to 36", Top Mounted Valve, Slots0.2 MM
101
Flanged 6", Tank 21" to 36", Top Mounted Valve, Slots 0.2 MM
102
Threaded 4", Tank 21" to 36", Side Mounted Valve, Top Distribution
103
System, Elbow 63 MM, External Glue Connection
103
Threaded 4", Tank 21" to 36", Side Mounted Valve, Bottom Distribution System, Elbow 63 MM, External Glue Connection
104
Threaded 4", Tank 21" to 36", Side Mounted Valve, Top Distribution System, Straight 63 MM, External Glue Connection
105
Threaded 4", Tank 21" to 36", Side Mounted Valve, Bottom Distribution System, Straight 63 MM, External Glue Connection
106
Flanged 6", Tank 21" to 36", Side Mounted Valve, Top Distribution System, External Flange 65 MM Connection
107
Flanged 6", Tank 21" to 36", Side Mounted Valve, Bottom Distribution System, External Flange 65 MM Connection
108
Flanged 6", Tank 42" to 63", Side Mounted Valve, Top Distribution System, External Flange 80 MM Connection
110
Flanged 6", Tank 42" to 63", Side Mounted Valve, Bottom Distribution System, External Flange 80 MM Connection
112
Hot Water, Flanged 6", Tank 42" to 63", Side Mounted Valve, Top and Bottom Distribution System, External Flange 80 MM Connection
114
Slots 0.2 MM
114
Hot Water, Flanged 6", Tank 21" to 36", Side Mounted Valve, Top and Bottom Distribution System, External Flange 65 MM Connection
116
Slots 0.2 MM
116
DLFC Parts List
117
Meters Parts List
118
Kit Meter & Meter Cables List
119
Other Components List
119
Disposal
120
Advertisement
Pentair FLECK 3150 NXT Installer Manual (190 pages)
Brand:
Pentair
| Category:
Water Dispenser
| Size: 5 MB
Table of Contents
Table of Contents
2
Generalities
7
Scope of the Documentation
7
Release Management
7
Manufacturer Identifier, Product
7
Intended Use
8
Abbreviations Used
8
Norms
8
Applicable Norms
8
Available Certificates
9
Procedure for Technical Support
9
Copyright and Trademarks
9
Limitation of Liability
10
Pentair Scan Application
11
Safety
12
Safety Pictograms Definition
12
Serial Label Location
13
Hazards
13
Personnel
13
Material
13
Hygiene and Sanitization
14
Sanitary Issues
14
Hygiene Measures
14
Description
15
Technical Specifications
15
Performance Flow Rate Characteristics
17
Outline Drawing
17
Components Description and Location
18
With NXT Controller and AC Motor
18
With NXT Controller and DC Motor
21
With NXT2 Controller and DC Motor
24
System Regeneration Cycle
26
Downflow Regeneration Cycle (5-Cycles Operation)
26
Upflow Regeneration Cycle (5-Cycles Operation)
28
Filter Cycle (3-Cycles Operation)
30
Injector Block Position for DF and UF Configurations
32
System Sizing
33
Recommended Injector/Dlfc/Blfc-Valve Configuration
33
Sizing a Softener (Single Unit)
33
Parameters to be Considered
33
Determining the Required Volume of Resin
34
Resin Exchange Capacity and Capacity of the Unit
35
Valve Configuration
36
Cycle Time Calculation
37
Salt Amount Definition
40
Injector Flow Rates
40
Installation
43
Warnings
43
Safety Notices for Installation
43
Installation Environement
43
General
43
Water
44
Electrical
44
Mechanical
45
Integration Constraints
45
Block Diagram and Configuration Example
47
Valve on Tank Assembly
48
Valve Connection to Piping
49
Top-Mounted Valve Installation
49
Side-Mounted Valve Installation
52
Regeneration Flows
53
Single Valve (System 4)
54
Multiple Valves, Parallel Interlock System (System 5)
54
Multiple Valves, Parallel Series Regeneration System (System 6)
54
Duplex Alternating Immediate System (System 7)
55
Duplex Alternating Delayed System (System 8) (NXT2 Only)
56
Multiple Valves, Parallel System with Standby Unit (System 9)
56
Multiple Valves, System On-Demand (System 14)
57
Electrical Connections
61
NXT Controller Connections
62
NXT2 Controller Connections
63
NXT Controller Connections for Multiple Valves
64
NXT2 Controller Connections for Multiple Valves
65
Bypassing
66
Drain Line Connection
66
Overflow Line Connection
67
Brine Line Connection
68
Programming
69
NXT Controller
69
Pentair FLECK 3150 NXT Installer Manual (182 pages)
Brand:
Pentair
| Category:
Control Unit
| Size: 5 MB
Table of Contents
Table of Contents
2
1 Generalities
7
Scope of the Documentation
7
Release Management
7
Manufacturer Identifier, Product
7
Intended Use
7
Abbreviations Used
7
Norms
8
Applicable Norms
8
Available Certificates
9
Procedure for Technical Support
9
Copyright
9
Limitation of Liability
9
Scan & Service Application
10
2 Safety
11
Safety Pictograms Definition
11
Serial Label Location
11
Hazards
11
Personnel
12
Material
12
Hygiene and Sanitization
12
Sanitary Issues
12
Hygiene Measures
13
3 Description
14
Technical Specifications
14
Performance Flow Rate Characteristics
16
Outline Drawing
16
Components Description and Location
17
With NXT Controller and AC Motor
17
With NXT Controller and DC Motor
18
With NXT2 Controller and DC Motor
19
System Regeneration Cycle
20
DF Regeneration Cycle (5-Cycles Operation)
20
UF Regeneration Cycle (5-Cycles Operation)
22
Filter Cycle (3-Cycles Operation)
24
Injector Block Position for DF and UF Configurations
26
4 System Sizing
27
Recommendations
27
Injector/Dlfc/Blfc-Valve Configuration
27
Sizing a Softener (Single Unit)
27
Parameters to be Considered
27
Determining the Required Volume of Resin
28
Resin Exchange Capacity and Capacity of the Unit
29
Valve Configuration
31
Cycle Time Calculation
31
Salt Amount Definition
34
1800 Injector Flow Rates
34
5 Installation
37
Warnings
37
Safety Notices for Installation
37
Installation Environement
38
General
38
Water
38
Electrical
38
Mechanical
39
Integration Constraints
39
Valve Connection to Piping
40
Top-Mounted Valve Installation
40
Side-Mounted Valve Installation
42
Block Diagram and Configuration Example
43
System Types
44
Single Valve (System #4)
45
Multiple Valves, Parallel Interlock System (System #5)
45
Multiple Valves, Parallel Series Regeneration System (System #6)
46
Duplex Alternating Immediate System (System #7)
46
Duplex Alternating Delayed System (System #8) (NXT2 Only)
47
Multiple Valves, Parallel System with Standby Unit (System #9)
47
Multiple Valves, System On-Demand (System #14)
48
Electrical Connections
52
NXT Controller Connections
53
NXT2 Controller Connections
54
NXT Controller Connections for Multiple Valves
55
NXT2 Controller Connections for Multiple Valves
56
Bypassing
57
Drain Line Connection
57
Overflow Line Connection
58
Brine Line Connection
59
6 Programming
60
NXT Controller
60
Display
60
Advertisement
Advertisement
Related Products
Pentair FLECK 3900
Pentair FLECK3150 DOWNFLOW
Pentair FLECK 2750 Downflow
Pentair Fleck 2510 ECONOMINDER
Pentair FLECK 5800
Pentair FLECK 5810
Pentair FLECK 9000 SXT
Pentair FLECK 2850 SXT
Pentair FLECK 2750 NXT
Pentair FLECK 2910
Pentair Categories
Water Pump
Water Filtration Systems
Control Unit
Water Dispenser
Controller
More Pentair Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL