11.6.6 Tank

EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
This function defines how much the water temperature may drop below the
desired leaving water temperature before the compressor stops. The compressor
will start up again when the leaving water temperature rises above the desired
leaving water temperature.
#
Code
N/A
[9-09]
Antifrost
Antifrost [1.4] or [4.C] prevents the room from getting too cold. For more
information about room frost protection, see "11.6.2 Room" [
Overview
The following items are listed in the submenu:
5
Additional zone
Space heating/cooling

Tank

User settings
Information
Tank setpoint screen
You can set the domestic hot water temperature using the setpoint screen. For
more information about how to do this, see
Powerful operation
You can use powerful operation to immediately start heating up the water to the
preset value (Storage comfort). However, this consumes extra energy. If powerful
operation is active,
To activate powerful operation
Activate or deactivate Powerful operation as follows:
1 Go to [5.1]: Tank > Powerful operation
2 Turn powerful operation Off or On.
Undershoot:
1°C~18°C
[5] Tank
Setpoint screen
[5.1] Powerful operation
[5.2] Comfort setpoint
[5.3] Eco setpoint
[5.4] Reheat setpoint
[5.5] Schedule
[5.6] Heat up mode
[5.7] Disinfection
[5.8] Maximum
[5.9] Hysteresis
[5.A] Hysteresis
[5.B] Setpoint mode
[5.C] WD curve
[5.D] Margin
[5.E] WD curve type
"11.3.5 Setpoint
will be shown on the home screen.
11
Configuration
|
Description
4
 149].
4
screen" [
 132].
Installer reference guide