3 If necessary, connect the separate normal kWh rate power supply.
INFORMATION
Some types of preferential kWh rate power supply require a separate normal kWh
rate power supply to the outdoor unit. This is required in the following cases:
if the preferential kWh rate power supply is interrupted when active, OR
if no power consumption of the hydro module of the outdoor unit is allowed at
the preferential kWh rate power supply when active.
4 Connect the preferential power supply contact.
3N~
OR
L N
L1 L2 L3 N
X1M
L
N
1N~, 50 Hz,
230 V AC, 6.3 A
X2M
S1S
X5M.10
X5M.9