Daikin EBLA09D V3 Series Installer's Reference Manual page 193

Hide thumbs Also See for EBLA09D V3 Series:
Table of Contents

Advertisement

EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
• [E-05]: Can the system prepare domestic hot water?
• [E-06]: Is a domestic hot water tank installed in the system?
• [E-07]: What kind of domestic hot water tank is installed?
In case of EKHWP, we recommend to use the following settings:
#
Code
[9.2.1]
[E‑07]
Tank type
N/A
[4-05]
Thermistor type
[5.8]
[6-0E]
Maximum tank
temperature
In case of EKHWS*D* / EKHWSU*D*, we recommend to use the following settings:
#
Code
[9.2.1]
[E‑07]
Tank type
N/A
[4-05]
Thermistor type
[5.8]
[6-0E]
Maximum tank
temperature
In case of a third-party tank, we recommend to use the following settings:
#
Code
[9.2.1]
[E‑07]
Tank type
N/A
[4-05]
Thermistor type
[5.8]
[6-0E]
Maximum tank
temperature
Item
Item
EKHWS*D* / EKHWSU*D*
Item
11
Configuration
|
EKHWP
5: EKHWP/HYC
0: Automatic
≤70°C
0: EKHWS/E
0: Automatic
≤75°C
Third-party tank
0: EKHWS/E
0: Automatic
≤75°C