Daikin EBLA09D V3 Series Installer's Reference Manual page 259

Hide thumbs Also See for EBLA09D V3 Series:
Table of Contents

Advertisement

EBLA09~16D▲V3▼ (1N~), EDLA09~16D▲V3▼ (1N~), EBLA09~16D▲W1▼ (3N~) and EDLA09~16D▲W1▼
(3N~)
A
g
h
i
j
b
e
f
R4T
a
c
A Hydro module
B Compressor module
a Water IN (screw connection, male, 1")
b Water OUT (screw connection, male, 1")
c Drain valve (water circuit)
d Plate heat exchanger
e Flow sensor
f Expansion vessel
g Safety valve
h Manual air purge valve
i Pump
j Connection for optional flow switch
k Liquid stop valve with service port
l Gas stop valve with service port
m Filter
n Rectifier
o Economiser
p Heat sink
q Distributor
r Heat exchanger
s Service port 5/16" flare
t Accumulator
u Muffler
EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
m
B1PW
S1NPH
l
R1T
d
k
R3T
Y1S
u
u
S1PH
M1C
t
1N~
*
B1PW Space heating water pressure sensor
M1C Compressor
S1PH High pressure switch
S1PL Low pressure switch
S1NPH Pressure sensor
Y1E Electronic expansion valve (main)
Y3E Electronic expansion valve (injection)
Y1S Solenoid valve (4-way valve)
Thermistors (hydro module):
R1T Outlet water heat exchanger
R3T Refrigerant liquid side
R4T Inlet water
Thermistors (compressor module):
R1T Outdoor air
R2T Compressor discharge
R3T Compressor suction
R4T Air heat exchanger
R5T Air heat exchanger, middle
Refrigerant flow:
Heating
Cooling
Connections:
Screw connection
Flare connection
Quick coupling
Brazed connection
17
Technical data
|
B
m
n
**
Y1E
p
Y3E
*
o
3N~
1N~
3N~
*
**
**
r
R5T
q
s
3D128954A
Installer reference guide