Electrical installation
Installer reference guide
104
K2M/1
K5M/13
K2M/3
K2M/5
K2M/3
K2M/5
K1M/5
K2M/1
Example measure resistance between K1M/1 and K5M/13:
Ω
Ω
To connect the backup heater kit to the outdoor unit
The wiring between the backup heater kit and the outdoor unit is as follows:
A
X3M
1
2
3
B
X15M
6
7
8
HV
A Outdoor unit
B Backup heater kit
HV High voltage connections (backup heater thermal protector + backup heater
connection)
LV Low voltage connection (backup heater thermistor)
NOTICE
The distance between the high voltage and low voltage cables should be at least
50 mm.
1 On the backup heater kit, connect the LV and HV cables to the appropriate
terminals as shown in the illustration below.
3 kW
6 kW
1N~ 230 V
1N~ 230 V
26.5Ω
52.9Ω
52.9Ω
132.3Ω
K1M
K2M
K2M
1 3 5 13
1 3 5 13
2 4 6 14
2 4 6 14
K5M
1 3 5 13
2 4 6 14
4
5
X5M
1
2
9 10
X15M
1
2
LV
EKLBUHCB6W
6 kW
9 kW
3N~ 400 V
3N~ 400 V
52.9Ω
52.9Ω
52.9Ω
52.9Ω
52.9Ω
52.9Ω
EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05