Daikin EBLA09D V3 Series Installer's Reference Manual page 43

Hide thumbs Also See for EBLA09D V3 Series:
Table of Contents

Advertisement

EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
CAUTION
If there is more than one leaving water zone, ALWAYS install a mixing valve station in
the main zone to decrease (in heating)/increase (in cooling) the leaving water
temperature when the additional zone has demand.
Typical example:
Room (zone)
Living room (main zone)
Bed rooms (additional zone)
(a)
In cooling mode, you can allow the underfloor heating (main zone) to provide refreshment
(no real cooling), or NOT allow it. See setup below.
Setup
A Additional leaving water temperature zone
B Room 1
C Room 2
D Main leaving water temperature zone
E Room 3
a User interface (delivered as accessory)
b Heat pump convectors (+ controllers)
c Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat)
d Mixing valve station
e Pressure regulating valve
INFORMATION
A pressure regulating valve should be implemented before the mixing valve station.
This is to guarantee the correct water flow balance between the main leaving water
temperature zone and the additional leaving water temperature zone in relation to
the required capacity of both water temperature zones.
For more information about connecting the electrical wiring to the unit, see
"9.2 Connections to the outdoor
Heat emitters: Design temperature
Underfloor heating:
In heating: 35°C
In cooling
no real cooling allowed)
Heat pump convectors:
In heating: 45°C
In cooling: 12°C
B
A
D
b
a
M1
e
d
4
unit" [
 91].
6
Application guidelines
|
(a)
: 20°C (only refreshment,
C
b
E
c
Installer reference guide
43