Main Zone; Ebla09~16D + Edla09~16D - Daikin EBLA09D V3 Series Installer's Reference Manual

Hide thumbs Also See for EBLA09D V3 Series:
Table of Contents

Advertisement

11
|
Configuration

11.6.3 Main zone

Installer reference guide
154
If room buffering is enabled, the extra energy from photovoltaic panels is buffered
in the DHW tank and in the space heating/cooling circuit (i.e. heat up or cool down
the room). With the room comfort setpoints (cooling/heating) you can modify the
maximum/minimum setpoints that will be used when buffering the extra energy in
the space heating/cooling circuit.
#
Code
[1.9.1]
[9-0A]
[1.9.2]
[9-0B]
Overview
The following items are listed in the submenu:
2
Malfunctioning
Room

Main zone

Additional zone
Space heating/cooling
Setpoint screen
Control the leaving water temperature for the main zone via setpoint screen [2]
Main zone.
See
"11.3.5 Setpoint
screen" [
Schedule
Indicate if the temperature of the leaving water is defined according to a schedule
or not.
Influence of the LWT setpoint mode [2.4] is as follows:
In Fixed LWT setpoint mode, the scheduled actions consist of desired leaving
water temperatures, either preset or custom.
In Weather dependent LWT setpoint mode, the scheduled actions consist of
desired shift actions, either preset or custom.
Description
Heating comfort setpoint
[3-07]~[3-06]°C
Cooling comfort setpoint
[3-09]~[3-08]°C
[2] Main zone
Setpoint screen
[2.1] Schedule
[2.2] Heating schedule
[2.3] Cooling schedule
[2.4] Setpoint mode
[2.5] Heating WD curve
[2.6] Cooling WD curve
[2.7] Emitter type
[2.8] Setpoint range
[2.9] Control
[2.A] Ext thermostat type
[2.B] Delta T
[2.C] Modulation
[2.E] WD curve type
4
 132].

EBLA09~16D + EDLA09~16D

Daikin Altherma 3 M
4P620241-1B – 2022.05

Advertisement

Table of Contents
loading

Table of Contents