Daikin EBLA09D V3 Series Installer's Reference Manual page 27

Hide thumbs Also See for EBLA09D V3 Series:
Table of Contents

Advertisement

EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
INFORMATION
The remote indoor sensor can only be used in case the user interface is
configured with room thermostat functionality.
You can only connect either the remote indoor sensor or the remote outdoor
sensor.
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure the outdoor
temperature.
As an option the remote outdoor sensor can be installed to measure the outdoor
temperature on another location (e.g. to avoid direct sunlight) to have an
improved system behaviour.
For installation instructions, see the installation manual of the remote outdoor
sensor and the addendum book for optional equipment.
INFORMATION
You can only connect either the remote indoor sensor or the remote outdoor sensor.
PC cable (EKPCCAB4)
The PC cable makes a connection between the hydro PCB (A1P) of the outdoor unit
and a PC. It gives the possibility to update the hydro software and EEPROM.
For installation instructions, see:
Installation manual of the PC cable
"11.1.2 To connect the PC cable to the switch
Heat pump convector (FWX*)
For providing space heating/cooling, it is possible to use the following heat pump
convectors:
FWXV: floor-standing model
FWXT: wall-mounted model
FWXM: concealed model
For installation instructions, see:
The installation manual of the heat pump convector
The installation manual of the heat pump convector options
The addendum book for optional equipment
External backup heater kit (EKLBUHCB6W1) + bypass valve kit (EKMBHBP1)
For models without integrated backup heater, you can install the external backup
heater kit (EKLBUHCB6W1).
For installation instructions, see:
Installation manual of the external backup heater kit
"To connect the backup heater
installation manual of the backup heater)
If you install the external backup heater kit, then under certain conditions you also
need to install a bypass valve kit (EKMBHBP1). See:
"Bypass valve kit
necessity" [
5
About the units and options
|
box" [
kit"  [
4
  102] (this topic partially supersedes the
4
 106]
4
 126]
Installer reference guide
27

Advertisement

Table of Contents
loading