Configuration
Forced defrost
Overview field settings
Export MMI settings
Installer reference guide
216
#
Code
[9.G]
N/A
Forced defrost
Manually start a defrost operation.
#
Code
[9.H]
N/A
NOTICE
Forced defrost start-up. You can only start forced defrost when the heating
operation has been running for a while.
Almost all settings can be done using the menu structure. If for any reason it is
required to change a setting using the overview settings, then the overview
settings can be accessed in the field settings overview [9.I]. See
4
overview
setting" [
125].
About exporting the configuration settings
Export the configuration settings of the unit to a USB memory stick, via the MMI
(the user interface delivered as accessory). When troubleshooting, these settings
can be provided to our Service department.
#
Code
[9.N]
N/A
To export MMI settings
1 Insert a USB memory stick in the user interface.
2 On the user interface, go to [9.N] Export MMI settings.
3 Select OK.
Description
Disable protections:
▪
0: No
▪
1: Yes
Description
Do you want to start a defrost operation?
▪
Back
▪
OK
Description
Your MMI settings will be exported
to the connected storage device:
▪
Back
▪
OK