Daikin EBLA09D V3 Series Installer's Reference Manual page 41

Hide thumbs Also See for EBLA09D V3 Series:
Table of Contents

Advertisement

Combination: Underfloor heating + Heat pump convectors – Multiple rooms
EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
The desired room temperature is set via the controller of the heat pump
convectors. There are different controllers and setups possible for the heat pump
convectors. For more information, see:
-
The installation manual of the heat pump convectors
-
The installation manual of the heat pump convector options
-
The addendum book for optional equipment
The user interface connected to the outdoor unit decides the space operation
mode.
The heating or cooling demand signals of each heat  pump convector are
connected in parallel to the digital input on the outdoor unit (X2M/35 and
X2M/30). The outdoor unit will only supply leaving water temperature when
there is an actual demand.
INFORMATION
To increase comfort and performance, we recommend to install the valve kit option
EKVKHPC on each heat pump convector.
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
Benefits
Compared with heat pump convectors for one room:
Comfort. You can set the desired room temperature, including schedules, for
each room via the remote controller of the heat pump convectors.
Setup
A Main leaving water temperature zone
B Room 1
C Room 2
a User interface (delivered as accessory)
b External room thermostat
1 (External room thermostat):
Unit operation is decided by the
external thermostat.
0 (Single zone): Main
B
A
M1
M1
a
6
Application guidelines
|
Value
C
c
b
Installer reference guide
41