Pin Assignment, Device Plug; Preparing The Measuring Device; Connecting The Measuring Device - Endress+Hauser Proline Cubemass C 100 Operating Instructions Manual

Coriolis flowmeter
Hide thumbs Also See for Proline Cubemass C 100:
Table of Contents

Advertisement

Proline Cubemass C 100 Ethernet/IP
Endress+Hauser
7.2.4

Pin assignment, device plug

Supply voltage
Pin
2
1
2
1
3
3
5
4
4
5
A0016809
Coding
Device plug for signal transmission (device side)
Pin
2
1
2
1
3
3
4
4
Coding
A0016812
7.2.5

Preparing the measuring device

NOTICE
Insufficient sealing of the housing!
Operational reliability of the measuring device could be compromised.
Use suitable cable glands corresponding to the degree of protection.
1. Remove dummy plug if present.
2. If the measuring device is supplied without cable glands:
Provide suitable cable gland for corresponding connecting cable.
3. If the measuring device is supplied with cable glands:
Observe requirements for connecting cables →  27.
7.3

Connecting the measuring device

NOTICE
Limitation of electrical safety due to incorrect connection!
Have electrical connection work carried out by appropriately trained specialists only.
Observe applicable federal/national installation codes and regulations.
Comply with local workplace safety regulations.
Always connect the protective ground cable  before connecting additional cables.
For use in potentially explosive atmospheres, observe the information in the device-
specific Ex documentation.
The power unit must be tested to ensure it meets safety requirements (e.g. PELV,
SELV).
L+
L-
A
+
+
-
-
D
Electrical connection
Assignment
DC 24 V
Not assigned
Not assigned
DC 24 V
Grounding/shielding
Plug/socket
Plug
Assignment
Tx
Rx
Tx
Rx
Plug/socket
Socket
29