Diagnostic
Short text
number
Diagnostic of sensor
022
Sensor temperature
046
Sensor limit exceeded
062
Sensor connection
082
Data storage
083
Memory content
140
Sensor signal
144
Measuring error too high
190
Special event 1
191
Special event 5
192
Special event 9
Diagnostic of electronic
201
Device failure
242
Software incompatible
252
Modules incompatible
262
Module connection
270
Main electronic failure
271
Main electronic failure
272
Main electronic failure
273
Main electronic failure
274
Main electronic failure
283
Memory content
311
Electronic failure
311
Electronic failure
382
Data storage
383
Memory content
Diagnostics and troubleshooting
Remedy instructions
1. Change main electronic
module
2. Change sensor
1. Inspect sensor
2. Check process condition
1. Change main electronic
module
2. Change sensor
1. Check module connections
2. Contact service
1. Restart device
2. Contact service
1. Check or change main
electronics
2. Change sensor
1. Check or change sensor
2. Check process conditions
Contact service
Contact service
Contact service
1. Restart device
2. Contact service
1. Check software
2. Flash or change main
electronics module
1. Check electronic modules
2. Change electronic modules
1. Check module connections
2. Change main electronics
Change main electronic module
1. Restart device
2. Change main electronic
module
1. Restart device
2. Contact service
Change electronic
Change electronic
1. Reset device
2. Contact service
1. Reset device
2. Contact service
1. Do not reset device
2. Contact service
1. Insert DAT module
2. Change DAT module
1. Restart device
2. Check or change DAT module
3. Contact service
Status
Diagnostic
signal
behavior
[from the
[from the
factory]
factory]
F
Alarm
S
Alarm
F
Alarm
F
Alarm
F
Alarm
S
Alarm
F
Alarm
F
Alarm
F
Alarm
1)
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
S
Warning
F
Alarm
F
Alarm
M
Warning
F
Alarm
F
Alarm