• Digital I/Os: 5 inputs and 5 outputs (open collector).
- 4 independent sink-driver auxiliary output signals, used to connect TTL or
non-TTL devices (up to 24 V).
- 1 strobe output (current source).
- 4 independent opto-isolated auxiliary input signals (implemented using
high-speed opto-isolators).
- 1 opto-isolated trigger input signal (implemented using a high-speed
opto-isolator).
- Input signals have interrupt generation capabilities.
Note that you cannot generate a strobe signal before the trigger or exposure
signal without using a hardware trigger from a third-party device.
• Timers: 2 exposure timers and 1 hi-drive timer.
- 2 exposure timers. One is used to generate the exposure signal and the other is
used to generate the strobe signal.
- 1 hi-drive timer used to control the time during which the maximum current
(500 mA) is applied to the strobe signal.
S o f t w a r e e n v i r o n m e n t
Your Matrox Iris GT uses Microsoft Windows Embedded CE (headless
configuration with TCP/IP, telnet, HTTP, and FTP services).
It requires that your client computer have the following:
• Microsoft Windows XP SP2 or above, or Microsoft Windows Vista.
• Up to 310 Mbytes of free hard disk space.
• Microsoft Internet Explorer 7.0, DirectX 9.0.
• 100/1000 BaseT Ethernet port.
M a t r o x I r i s G T s m a r t c a m e r a s u m m a r y