U s e r L E D b l i n k s e q u e n c e
6 - 1 - 3 - 4 - 2
6 - 1 - 4 - 1 - 1
6 - 1 - 4 - 1 - 3
6 - 1 - 4 - 1 - 4
6 - 1 - 4 - 2 - 1
6 - 1 - 4 - 2 - 2
6 - 1 - 4 - 2 - 3
6 - 1 - 4 - 2 - 4
6 - 1 - 4 - 3 - 1
6 - 1 - 4 - 3 - 2
6 - 1 - 4 - 3 - 3
For example, the power and user LEDs have the following blink sequence when
a boot parameter block error occurs.
• The power LED is red and constant.
• The User LED flashes 16 times (6-1-4-2-3). The flashes are divided into groups
(pulses) with a 300 msec pause between each pulse. A 1 second pause occurs before
the blink pattern repeats.
When the User LED stops blinking. The error code is complete.
Note that your Matrox Iris GTmight stop the bootloader execution when an error
occurs. Any critical error will prevent your Matrox Iris GT from continuing the
boot process.
E r r o r
C P U t e m p e r a t u r e t o o h i g h .
E t h e r n e t S E E P R O M e r r o r .
S e n s o r b o a r d S E E P R O M c o m m u n i c a t i o n e r r o r .
S e n s o r b o a r d S E E P R O M d a t a e r r o r .
S e n s o r b o a r d t e m p e r a t u r e s e n s o r c o m m u n i c a t i o n e r r o r .
S e n s o r b o a r d t e m p e r a t u r e t o o h i g h .
B o o t p a r a m e t e r s b l o c k e r r o r .
B o o t p a r a m e t e r s b l o c k d a t a e r r o r .
S e n t m a x i m u m b o o t t i m e w i t h n o a n s w e r e r r o r .
O p e r a t i n g s y s t e m d o w n l o a d e d t h r o u g h E t h e r n e t i s n o t v a l i d .
O p e r a t i n g s y s t e m i m a g e o n t h e s o l i d s t a t e d r i v e i s n o t v a l i d .
P o w e r L E D e r r o r c o d e s
1 1 3