3. Remove the imaging kit.
4. Remove the toner cartridges.
5. Unpack the new imaging kit, and then remove the packing material.
Note: The imaging kit includes the imaging kit and the cyan, magenta, and yellow developer units.
6. Remove the black imaging unit.
Warning—Potential Damage: Do not expose the photoconductor unit to direct light for more than 10 minutes.
Extended exposure to light may cause print quality problems.
Warning—Potential Damage: Do not touch the shiny photoconductor drum under the imaging unit. Doing so
may affect the quality of future print jobs.
MX-C507P [4] REPLACING PARTS AND SUPPLIES 4-6