8. Set all eight anti-tilt wires in the liquid-cooling loop to the outward position (see Letter A).
9. Using a T30 Torx* screwdriver, tighten the cold plate fasteners to 8 in-lb (see Letter B). No specific
sequence is needed. General diagonal bolt tightening order can be used.
10. Unscrew all 12 captive screws on the plastic carrier (see Letter A) and carefully lift the carrier away from
the module (see Letter B).
Intel® Server D50DNP Family Integration and Service Guide

Figure 42. Securing the Processor Cold Plates

Figure 43. Removing Liquid-Cooling Loop Carrier