3-4-3
Read Controller information
This service reads the Controller's model and version.
Command
Service Request PDU
MRC
0
5
0
2
2
Response
Service Response PDU
MRC
SRC
0
5
0
2
2
(1) Model data
The model number is returned in 20 bytes of ASCII data. If the data is less than 20 bytes long, the remaining
bytes will be padded with spaces (20 hex).
The following table shows the model number format.
Model
KPxxxx-OD-xx
(2) Version data
The version number is returned in 20 bytes of ASCII data. If the data is less than 20 bytes long, the remaining
bytes will be padded with spaces (20 hex).
Version
V1.00
(3) Response Codes
Response
code
(MRES+SRES)
1001
Command too long
0000
Normal completion
Grid Connect Photovoltaic Inverter KPG/KPL Communication Manual
SRC
1
Response code
(MRES+SRES)
1
4
Model data
KPxxxx-OD-xx-xx (Space code)
Version data
1.00(Space code)
Error name
The command is too long.
No error.
Model data
20
Error
Cause
priority
1
None
3 Compoway/F
Version data
20
3 - 13
3