To configure LAN parameters using a logic analysis
system without an emulation module
1 Connect the LAN cable to the connector on the emulation probe.
2 In the logic analysis system interface, open the Workspace window by
selecting the Workspace icon.
3 Scroll down the left side of the toolbox in the workspace window and
find the emulation probe tool. Drag the emulation probe icon from the
toolbox to the workspace.
4 From the emulation probe icon, select Init Probe LAN Addresses....
5 Enter the link-level address of the probe you wish to set up.
6 Enter the internet address, gateway IP and subnet mask in the
appropriate fields.
7 Select OK.
If "ERROR - no response from emulation probe" is displayed, check that the
emulation probe is properly connected to the LAN. Then try selecting OK
again.
If no error message is displayed, the internet address and other network
parameters will be stored in nonvolatile memory and will take effect when
power is cycled.
8 Cycle power on the emulation probe by powering it off then on again.
Agilent Technologies Emulation for the PowerPC 400/600/700
Chapter 4: Connecting the Emulation Probe to a LAN
Connecting the Emulation Probe to a Site LAN