Chapter 12: Troubleshooting the Emulation Probe
Problems with the LAN Interface
❏ Watch the LAN LED's to see whether the emulation probe is seeing LAN
activity. The LED's are described on page 156. Refer to your LAN
documentation for information on testing connectivity.
❏ It's also possible for there to be a problem with the emulation probe
firmware while the LAN interface is still up and running. In this case, you
must reboot the emulation probe by turning the emulation probe power
switch off then on again.

If you have LAN connection problems

❏ Verify the IP address and gateway mask of the emulation probe. To do this,
connect the emulation probe to a terminal or terminal emulator and enter
the lan command (see See "To configure LAN parameters using a serial
connection" on page 42.).

If it takes a long time to connect to the network

❏ Check the subnet masks on the other LAN devices connected to your
network. All of the devices should be configured to use the same subnet
mask.
Subnet mask error messages do not indicate a major problem. You can
continue using the emulation probe.
If there are many subnet masks in use on the local subnet, the logic
analysis system may take a very long time to connect to the network after it
is turned on.
If you have problems setting the LAN parameters using
a logic analysis system
❏ If the E5900B emulation probe is not connected to an E5901B
emulation module, then make sure the emulation probe is on the same
subnet as the logic analysis system during initial setup; otherwise,
172