Chapter 12: Troubleshooting the Emulation Probe
Problems with the Target System
2 Check that the emulation probe firmware matches your processor. To
do this, enter:
M>ver

To check the debug port connector signals

• Check for the following logic levels on the target debug port.
Levels with the emulation probe not connected
Header Pin
Signal Name
3
TDI
4
TRST
6
+POWER
7
TCK
9
TMS
11
SRESET
13
HRESET
15
CHECKSTOP
16
GND
Levels with the emulation probe connected
Header Pin
Signal Name
1
TDO
3
TDI
4
TRST
6
+POWER
7
TCK
9
TMS
11
SRESET
13
HRESET
15
CHECKSTOP
16
GND
164
Level
Low
High/Low (depends on
pullup or pulldown).
V
DD
High
High
High
High
High
Low
I/O
Toggle with "es" command
Toggle with "es" command
High, pulse low with "rst" command
V
DD
10+ MHz clock (default)
Low, pulse with "es" command
High, pulse low with "rst" command
High, pulse low with "rst" command
High
Low