Replacing Transmission Oil Filter
1. See page G-13.
Changing Transmission Fluid
1. See page G-13.
Cleaning Transmission Oil Strainer
1. When changing the transmission fluid, disassemble and rinse the
strainer with nonflammable solvent to completely clean off
fillings.
2. When reassembling, be careful not to damage the parts.
NOTE
• Since the fine fillings in the oil can damage the precision
component parts of the hydraulic system, the end of the
suction line is provided with an oil strainer.
(1) Strainer
Changing Front Axle Case Oil
1. Park the machine on a firm, flat and level surface.
2. To drain the used oil, remove the right and left drain plugs and oil
gauge at the front axle case and drain the oil completely into the
oil pan.
3. After draining, reinstall the drain plugs.
4. Remove the right and left breather plugs.
5. Fill with new oil up to the upper notch on the dipstick.
IMPORTANT
• After ten minutes, check the oil level again; add oil to
prescribed level.
6. After filling, reinstall the oil gauge and breather plugs.
Front axle case oil capacity
(1) Breather Plug
(2) Oil Gauge with Dipstick
(3) Drain Plug
G-24
G GENERAL
W1019345
W1019295
(2) Filter Plate
W1019390
4.7 L
5.0 U.S.qts
4.1 Imp.qts
(A) Oil level is acceptable within this
range.