(2) Check Point of Initial 50 Hours

(3) Check Point of Every 150 Hours

(4) Check Point of Every 2 Years

Changing Gear Box Oil
CAUTION
• Be sure to stop the engine and remove the key before
changing the oil.
[RCK60B-23BX, RCK54-23BX]
1. Dismount the mower from the tractor, and place the mower on
level ground.
2. Remove the oil filler plug (2).
3. Remove the drain plug (1), and drain the used oil completely.
4. After draining the used oil, reinstall the drain plug.
5. Fill with new oil up to the specified level.
[RCK54P-23BX]
1. To drain the used oil, remove the oil filter plug (2) at the mower
gear box, tilt the mower deck and drain the oil completely into the
oil pan.
2. After draining, reinstall the filter plug (2).
3. Fill with new oil up to the filter plug port.
4. After filling, reinstall the oil filter plug (2).
IMPORTANT
• Use the specified gear oil.
Refer to "LUBRICANTS". (See page 7-S2.)
(1) Drain Plug
(2) Oil Filter Plug
Changing Gear Box Oil
1. See above.
Replacing Gear Box Oil Seal
1. Replace the gear box oil seals (1), (2) with new ones.
(1) Oil Seal
7-S7
ROTARY MOWER
[A] RCK60B-23BX, RCK54-23BX
[B] RCK54P-23BX
W1017456
W1017729
(2) Oil Seal