BX24, RCK54(P)-23BX, RCK60B-23BX, LA240, BT601, WSM

(2) Pump and Priority Valve

Checking Power Steering Oil Flow
IMPORTANT
• Use the instruction with the flowmeter when you use the
flowmeter.
• While testing, do not close the flowmeter loading valve
completely.
1. Disconnect the power steering controller hose (Inlet) (1) from the
power steering pipe (2).
2. Fix the inlet flow meter hose to the power steering pipe (2) and
the flow meter as shown in the photo.
3. Fix the flow meter return hose to the transmission fluid filling port
and the flow meter as shown in the photo.
4. Measure the flow volume of power steering.
The flow volume of pump is 8.0 L (2.1 U.S.gals, 1.8 Imp.gals) or
higher and verify the content below when the engine revolution is
-1
1500 min
(rpm).
5. If the flow volume varies from the specification, replace the
priority valve then take measurement again.
6. After measuring the flow volume, remove the flow meter then
reassembling the hydraulic pipe to the original position.
Condition
• Engine speed:
-1
1500 min
(rpm)
• Oil temperature:
45 to 55 °C (113 to 131 °F)
Power steering oil flow
Factory specification
(1) Power Steering Controller Hose
(Inlet)
5-S5
HYDRAULIC SYSTEM
Above
8.0 L/min.
2.1 U.S.gals/min.
1.8 Imp.gals/min.
(2) Power Steering Pipe
W1039384
KiSC issued 08, 2019 A