HPE ProLiant DL360 Gen11 User Manual page 137

Hide thumbs Also See for ProLiant DL360 Gen11:
Table of Contents

Advertisement

Specification
Specification
1
Temperature range
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit
and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
(2953 ft) to a maximum of 3048 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website
Mechanical specifications
Mechanical specifications
Specification
Specification
Value
Value
Height
4.29 cm (1.69 in)
Depth, SFF
75.31 cm (29.65 in)
Depth, LFF
77.30 cm (30.43 in)
Width
43.46 cm (17.11 in)
Weight, SFF minimum 14.50 kg (32 lb)
Weight, SFF maximum 21 kg (46 lb)
Weight, LFF minimum 14.50 kg (32 lb)
Weight, LFF maximum 22 kg (48 lb)
Power supply specifications
Power supply specifications
Depending on the installed options and the regional location where the server was purchased, the server can be configured with one of
the following power supplies:
HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply
HPE 1000 W Flex Slot Titanium Hot-plug Power Supply
HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website
(https://www.hpe.com/info/proliant/powersupply
https://www.hpe.com/info/proliant/powersupply).
Value
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
Minimum to be the higher (more moisture) of -12°C (10.4°F) dew
point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Hewlett Packard Enterprise website .
HPE ProLiant DL360 Gen11 Server User Guide
137

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents