CHAPTER 15

Troubleshooting Switch Components

Troubleshooting Network Interfaces on EX3200 and EX4200 Switches

The interface on one of the last four built-in network ports in an EX3200 switch (for example,
interface ge-0/0/23) is down
Problem
Cause
Solution
Copyright © 2010, Juniper Networks, Inc.
Troubleshooting Network Interfaces on EX3200 and EX4200 Switches on page 193
Troubleshooting Uplink Module Installation or Replacement on EX3200 and EX4200
Switches on page 194
This topic provides troubleshooting information for specific problems related to interfaces
on EX3200 and EX4200 switches.
The interface on one of the last four built-in network ports in an EX3200 switch (for
example, interface ge-0/0/23) is down on page 193
The interface on the port in which an SFP or SFP+ transceiver is installed in an SFP+
uplink module is down on page 194
The interface on one of the last four built-in ports (
24-port models or
ge-0/0/44
switch is down.
An SFP or SFP+ uplink module is installed in the switch and a transceiver is installed in
one of the ports on the uplink module.
When you check the status with the CLI command
user interface, the disabled port is not listed.
The last four built-in ports use the same ASIC as the SFP uplink module. Therefore, if
you install a transceiver in an SFP or SFP+ uplink module installed in an EX3200 switch,
a corresponding base port from the last four built-in ports is disabled.
If you need to use the disabled built-in port, you must remove the transceiver from the
SFP or SFP+ uplink module. Alternatively, you can install an XFP uplink module instead
of an SFP or SFP+ uplink module. There is no conflict between the built-in network ports
and the ports on the XFP uplink modules.
ge-0/0/20
through
on 48-port models) of an EX3200
ge-0/0/47
show interfaces ge-
through
on
ge-0/0/23
or with the J-Web
193