Table 28: Rack Requirements and Specifications for the Switch (continued)
Rack Requirement
Rack size and strength
Rack connection to
building structure
Related Topics

Cabinet Requirements for EX3200 and EX4200 Switches

94
Guidelines
Ensure that the rack complies with one of these standards:
A 19-in. rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document
number EIA-310–D) published by the Electronics Industry Association (
Ensure that the rack rails are spaced widely enough to accommodate the switch chassis' external
dimensions . The outer edges of the front-mounting brackets extend the width of the chassis to
19 in. (48.2 cm).
The rack must be strong enough to support the weight of the switch.
Ensure that the spacing of rails and adjacent racks allows for the proper clearance around the
switch and rack.
Secure the rack to the building structure.
If earthquakes are a possibility in your geographical area, secure the rack to the floor.
Secure the rack to the ceiling brackets as well as wall or floor brackets for maximum stability.
One pair of mounting brackets for mounting the switch on two posts of a rack is supplied
with each switch. For mounting the switch on four posts of a rack or cabinet, you can
order a four-post rack-mount kit separately.
Chassis Physical Specifications for EX3200 and EX4200 Switches on page 7
Rack-Mounting and Cabinet-Mounting Warnings for EX Series Switches on page 221
Clearance Requirements for Airflow and Hardware Maintenance for EX3200 and
EX4200 Switches on page 96
Mounting an EX3200 or EX4200 Switch on Two Posts in a Rack or Cabinet on page 122
Mounting an EX3200 or EX4200 Switch on Four Posts in a Rack or Cabinet on page 124
Mounting an EX3200 or EX4200 Switch in a Recessed Position in a Rack or Cabinet
on page 128
You can mount the switch in a cabinet that contains a 19-in. rack.
Cabinet requirements consist of:
Cabinet size
Clearance requirements
Cabinet airflow requirements
Table 29 on page 95 provides the cabinet requirements and specifications for the switch.
http://www.eia.org
Copyright © 2010, Juniper Networks, Inc.
).