Insert the mounting screws in the wall. Insert the top pair of mounting screws
3.
474.35 mm apart, and insert the second pair of mounting screws 151.81 mm directly
below the first set.
If the mounting screws are inserted in wall board with no stud behind it, you must
use dry wall anchors rated to support 75 lb (34 kg). Insert the screws into wall studs
wherever possible to provide added support for the chassis.
Screw the screws only part way in, leaving about 1/4 in. (6 mm) distance between
the head of the screw and the wall.
Grasp each side of the switch or switches, lift the switch or switches, and hang the
4.
brackets from the mounting screws as shown in Figure 45 on page 130.

Figure 45: Mounting an EX3200 or EX4200 Switch on a Wall

Rear panel
Hang attached brackets
on wall-mounted screws.
Tighten the mounting screws.
5.
If it is an EX4200-24F switch, we recommend you insert dust covers in unused SFP
6.
ports.
Connecting AC Power to an EX3200 or EX4200 Switch on page 147
Connecting DC Power to an EX3200 or EX4200 Switch on page 149
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 165
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 167
Wall-Mounting Warning for EX3200 and EX4200 Switches on page 225