Vu-meters settings
Click on the "Settings" button to adjust the bargraph display and the front panel LED vu-meters display (red zone, orange
zone, and green zones).
8.1.2.2.2 Audio I/O −> Output −> settings
This page allows the following:
●
assign a physical output or AoIP output to a decoder output signal
●
naming of the encoder outputs
●
Configure the AoIP output(s)
This page displays all the inputs proposed by your IQOYA.
The audio sources to be encoded (input Programs) are selected among these inputs.
X/LINK-ST & X/LINK-LE
When Analog is selected, an analog gain/attenuation is applied to the output signal. The value displayed
below the fader corresponds to the level of the output signal for a 0 dBfs digital signal.
Peak duration window: duration of the display of the peak levels (from 20ms to
10000ms)
Peak: Level value in dBfs above which the vu-meter is red
Headroom: Level value in dBfs above which the vu-meter is orange.
Nominal 1: Level value in dBfs above which the LED right below the headroom
LED is highlighted in green.
Nominal 2: Level value in dBfs above which the 3rd LED from the bottom is
highlighted in green.
Nominal 3: Level value in dBfs above which the 2nd LED from the bottom is
highlighted in green.
Nominal 4 :Level value in dBfs above which the 1rst LED from the bottom is
highlighted in green.
Displayed mono outputs
2 analog, 2 on AES/3, 2 AoIP(*)
IQOYA X/LINK range user manual
Number of mono outputs that can be selected for
output programs destinations
2
60