Sensor
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
sensor, they must be registered here.
Slot Number
Sensor ID : Multiple usage of sensors
of the same type requires an ID
be input. Tapping this will allow
for manual input, but see the next
page about how to perform auto-
registration via sensor registration.
<
>
The required
Sensor
number of slots
TEMP (SBS-01T/TE)
RPM (SBS01RM/RO/RB)
Voltage (SBS-01V)
Altitude (SBS-01/02A)
Current (SBS-01C)
S.BUS Servo sennsor
(SBS-01S)
GPS(SBS-01/02G)
TEMP125-F1713
VARIO-F1712
VARIO-F1672
CURR-F1678
GPS-F1675
Kontronik ESC
Castle TL0
JetCat V10
PowerBox
< Linkage menu >
92
Registered sensor
Tap the slot to display
sensors which can be used
for the start slot. Tap to
register the sensor.
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
The number which can be used as a start slot
1 slot
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
6 slots
8 slots
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
8 slots
8 slots
8 slots
1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 5 , 1 6 , 1 7 ,
14 slots
16 slots
[What is a slot?]
classified in units called "slot". There are slots from
No. 1 to No. 31.
Altitude sensors, GPS sensors and other data
sensor units may use multiple slots.
When using a sensor which uses two or more slots,
the required number of slots is automatically assigned
by setting up a start slot.
the sensors themselves must allocate unused slots and
memorize that slot.
This is what displays when no
s e n s o r i s r e g i s t e r e d i n a s l o t .
Tapping the slot and selecting
"-----------" will erase whatever was
registered there, freeing up the
slot.
1-31
1-31
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 ,
2 4 , 2 5 , 2 6
8 , 1 6 , 2 4
1-31
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
8 , 1 6 , 2 4
8 , 1 6 , 2 4
8 , 1 6 , 2 4
1 8
8 , 1 6
sensors are
Selling area
Global
Europe