Appendix; Transport, Storage, Maintenance, Disposal - Danaher Motion Kollmorgen SERVOSTAR 300 Series Assembly, Installation, Setup

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
7

Appendix

7.1

Transport, storage, maintenance, disposal

Transport :
Packaging :
Storage :
Maintenance : — the instruments do not require any maintenance
Cleaning :
Disposal :
®
SERVOSTAR
300 Installation Manual
12/05
— only by qualified personnel
— only in the manufacturer's original recyclable packaging
— avoid shocks
— temperature
-25 to +70°C, max. rate of change 20°C / hour
— humidity
max. 95% relative humidity, no condensation
— The servo amplifiers contain electrostatically sensitive components,
that can be damaged by incorrect handling. Discharge yourself
before touching the servo amplifier. Avoid contact with highly
insulating materials, such as artificial fabrics and plastic films.
Place the servo amplifier on a conductive surface.
— if the packaging is damaged, check the unit for visible damage.
In such an event, inform the shipper and the manufacturer.
— recyclable cardboard with inserts
— dimensions :
— labeling
— only in the manufacturer's original recyclable packaging
— the servo amplifiers contain electrostatically sensitive components
which can be damaged by incorrect handling. Discharge yourself
before touching the servo amplifier. Avoid contact with highly
insulating materials (artificial fabrics, plastic films etc.).
Place the servo amplifier on a conductive surface.
— max. stacking height 8 cartons
— storage temperature -25 to +55°C, max. rate of change 20°C / hour
— humidity
— storage duration
— opening the instruments invalidates the warranty
— if the casing is dirty: clean with isopropanol or similar
do not immerse or spray
— if there is dirt inside the unit: must be cleaned by the manufacturer
— dirty protective grill on fan: clean with a dry brush
— you can dismantle the servo amplifier into its principal components
by unscrewing it (aluminum heat sink, steel housing sections,
electronics boards)
— disposal should be carried out by a certified disposal company.
We can give you suitable addresses on request
(HxWxD) 115x365x275mm
instrument label on outside of box
5 ... 95% relative humidity, no condensation
< 1 year without restriction
> 1 year: capacitors must be re-formed before
setting up and operating the servo amplifier.
To do this, remove all electrical connections
and apply single-phase 230V AC for about
30 minutes to the terminals L1 / L2.