Motor Chokes 3Ylnxx - Danaher Motion Kollmorgen SERVOSTAR 300 Series Assembly, Installation, Setup

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
6.2.4

Motor chokes 3YLNxx

To use with motor cables longer than 25m up to 50m max. to reduce velocity ripple and to
protect the output power stage of the amplifier. The terminals BR are used to connect the
motor holding brake. Beside the terminal are block two shield connection terminals for
safe connection of the cables's shielding braid.
Mount the choke nearby the servo amplifier. The cable length between amplifier
and choke must never exceed 2m. Connection see page 42 .
The increased absorption reduces the permissible rotative frequency and limits thereby
the permitted motor speed:
— with 6 poles motors to n
— with 8 poles motors
— with 10 poles motors n
The increased leakage current at rising cable length leads to the reduction of usable
amplifier output current of about 1A. Use only motors with more than 2A rated current, to
get a good regulation quality.
Technical data
Rated current
Peak current
Winding inductance
Winding resistance
Power loss
Rotative frequ. (max)
Clock frequency
Test voltage
Overload
Climatic category
Weight
Connection diameter
A
B
C
D
E
F
®
SERVOSTAR
300 Installation Manual
12/05
= 3000 rpm
max
n
= 2250 rpm
max
= 1800 rpm
max
Dim
3YLN06
A
3x6
A
12
mH
0,9
Ohm
24,7
W
Hz
kHz
-
Phase<->PE 2700V DC 1s
A
-
DIN IEC 68 Part 1 25/085/21
kg
4,5
mm²
4
mm
155
mm
130
mm
70
mm
55
mm
190
mm
5,5 x 8
Expansions and Accessories
3YLN10
3YLN14
3x10
3x14
30
28
0,9
0,9
14,9
12,7
40
150
2 - 8
1,5 x Inom, 1 min/h
5,5
10
4
4
155
190
130
170
85
115
70
75
190
220
5,5 x 8
6,5 x 10
3YLN20
3x20
40
0,45
7,6
10
6
190
170
115
75
230
6,5 x 10
93

Advertisement

Table of Contents
loading

Table of Contents