Technical Data For Connecting Cables - Danaher Motion Kollmorgen SERVOSTAR 300 Series Assembly, Installation, Setup

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
3.4.3.2

Technical data for connecting cables

Further information on the chemical, mechanical and electrical characteristics of the
cables can be obtained from our customer service.
Observe the rules in the section "Conductor cross-sections" on page 21. To reach
the max. permitted cable length, you must use cable material that matches the
capacitance requirements listed below.
Insulation material
Sheathing
Core insulation
Capacitance
Motor cable
Resolver/Encoder cable - less than 120 pF/m
Technical data
Cores
[mm²]
(4x1.0)
(4x1.5)
(4x1.0+(2x0.75))
(4x1.5+(2x0.75))
(4x(2x0.25))
(7x(2x0.25))
* Danaher Motion North America supplies cables up to 39 meters
*
Danaher Motion Europe supplies cables up to max. length.
Motor cables longer than 25m only with motor choke 3YLNxx
®
SERVOSTAR
300 Installation Manual
- PUR (polyurethane, code 11Y)
- PETP (polyesteraphthalate, code 12Y)
- less than 150 pF/m
The brackets in the core definition indicate the shielding.
All cables are suitable for use as trailing cables.
The technical data refer to use as moveable cables.
Operating life : 1 million bending cycles
max.
length
[m]
50*
motor power
50*
motor power
motor power
50*
motor power
50*
100*
50*
12/05
Core
Use for
identi-
fication
number
number
color
+ brake
number
+ brake
Resolver
color
Encoder
color
Installation
Operating
Outside
temp. range
diameter
[°C]
[mm]
-30 / +80
10
-30 / +80
10.5
-30 / +80
10.5
-30 / +80
11.5
-30 / +80
6.9
-30 / +80
7.7
Bending
radius
[mm]
100
105
100
120
70
80
35