Master-Slave Operation, Encoder Master Control; Connection To A Servostar Master, 5V Signal Level (X5) - Danaher Motion Kollmorgen SERVOSTAR 300 Series Assembly, Installation, Setup

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
4.8

Master-slave operation, encoder master control

This interface can be used to link several SERVOSTAR 300 amplifiers together in mas-
ter-slave operation.
Parameter setting for the slave amplifier is carried out with the aid of the setup software
(electrical gearing). The resolution (no. of pulses/turn) can be adjusted, and the analog
setpoint inputs are out of action.
Signal diagram (for encoders with RS422 or 24V output)
4.8.1

Connection to a SERVOSTAR master, 5V signal level (X5)

This interface can be used to link several SERVOSTAR 300 amplifiers together in mas-
ter-slave operation. Up to 16 slave amplifiers can be controlled by the master, via the
encoder output. The SubD connector X5 is used for this purpose.
Frequency limit: 1.5 MHz, transition time tv £ 0.1µs
®
SERVOSTAR
300 Installation Manual
SERVOSTAR 300
12/05
Interfaces
SERVOSTAR
55