Interfaces
4.9.1

Connection to a stepper controller with 5V signal level (X5)

This interface can be used to connect the servo amplifier to a stepper-motor controller
with a 5V signal level. It uses the SubD connector X5.
Frequency limit: 1.5 MHz
4.9.2

Connection to a stepper controller with 24V signal level (X3)

This interface can be used to connect the servo amplifier to a stepper-motor controller
with a 24V signal level. It uses the digital inputs DIGITAL-IN 1 and 2 on connector X3.
Frequency limit: 100 kHz