Technical description
2.10

Technical data

2.10.1

Technical data for 110/230 V (types S3_ _6_)

Rated data
Order Code
Rated supply voltage
(grounded supply, phase to phase)
Rated input power for S1 operation
Max. DC bus link voltage
Rated output current (rms value, ± 3%)
Peak output current (rated current x 2 for approx. 5s, ± 3%)
Switching frequency of the output stage
Technical data for regen circuit
Threshold for overvoltage switch-off
Motor inductance min.
Motor inductance max.
Form factor of the output current
(rated conditions, min. load inductance)
Bandwidth of current controller
Residual voltage drop at rated current
Thermal dissipation, output stage disabled
Thermal dissipation at rated current
(incl. PSU losses, without regen dissipation)
Mechanical
Weight
Height, without connectors
Width
Depth, without connectors
Depth, with connectors
* at reduced current
18
at 1x110V
at 3x115V
at 3x230V
at 1x230/240V
at 1x110V
at 3x115V
at 3x230V
at 1x230/240V
at 1x110V
at 3x115V
at 3x230V
at 1x230/240V
12/05
DIM
V~
kVA
V=
Arms
Arms
Arms
Arms
Arms
Arms
Arms
Arms
kHz
VDC
mH
mH
mH
mH
mH
kHz
V
W
W
kg
mm
mm
mm
mm
SERVOSTAR
Kollmorgen
SERVOSTAR
303
306
S30361
S30661
1 x 110V
... 1 x 230V
-10%
3 x 110V
... 3 x 230V
-10%
50/60 Hz
1.1
2,4
450
3
3
3,5
8
3
6
3
4
5
5
9
15
9
15
9
9
8 (16*)
ð p.23
235 / 455
3,7
3,7
2,1
1,3
4,3
2,6
4,3
4,3
Consult our customer support
1.01
> 1.2
4
12
35
60
approx. 2,6
275
279
70
171