Auxiliary Supply (X4); Dc Bus Link (X8) - Danaher Motion Kollmorgen SERVOSTAR 300 Series Assembly, Installation, Setup

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
4.2.2
24V auxiliary supply (X4)
— External 24V DC power supply, electrically isolated, e.g. via an isolating transformer
— Required current rating ð p.18
— Integrated EMC filter for the 24V auxiliary supply
4.2.3

DC bus link (X8)

Terminals X8/1 (-DC) and X8/3 (+RBext). Can be connected in parallel, whereby the
regen power is divided between all the amplifiers that are connected to the same DC bus
link circuit.
SERVOSTAR 300
Only servo amplifiers with mains supply from the same mains (identical mains
supply voltage) may be connected by the DC bus link.
®
SERVOSTAR
300 Installation Manual
SERVOSTAR 300
12/05
Interfaces
SERVOSTAR 300
41

Advertisement

Table of Contents
loading

Table of Contents