Interfaces
4.8.2

Connection to incremental-encoder master with 24V signal level (X3)

This interface can be used to operate the SERVOSTAR as a slave, mastered by an enco-
der with a 24V signal level (master-slave operation).
This uses the digital inputs DIGITAL-IN 1 and 2 on connector X3.
Frequency limit: 100 kHz, transition time tv £ 0.1µs
4.8.3

Connection to a sine-cosine encoder master (X1)

This interface can be used to operate the SERVOSTAR as a slave, mastered by a
sine-cosine encoder (master-slave operation). This uses the SubD connector X1.
Frequency limit (A, B): 350 kHz