© National Instruments Corporation
4.
Set the analog path by calling the niFgen Property Node and selecting
Output Attributes»Analog Path.
LabVIEW Block Diagram
5.
Set the pre-amplifier attenuation by calling the niFgen Property Node
and selecting Calibration»Pre-Amplifier Attenuation.
LabVIEW Block Diagram
17
C/C++
Function Call
Call
niFgen_Set
AttributeViInt32
using the following
parameters:
vi: The session handle
returned from
.
niFgen_init
channelName:
"0"
attributeID:
NIFGEN_ATTR_
ANALOG_PATH
value: The Analog Path
value listed in Table 3
for the current iteration
C/C++
Function Call
Call
niFgen_Set
AttributeViReal64
using the following
parameters:
vi: The session handle
returned from
.
niFgen_init
channelName:
"0"
attributeID:
NIFGEN_
ATTR_PRE_AMPLIFIER_
ATTENUATION
value: The Pre-Amplifier
Attenuation value listed in
Table 3 for the current
iteration
NI 5402/5406 Calibration Procedure