Leakage Current in Power Down Mode

The leakage current in Power Down mode varies depending on the following conditions:
If the supply voltage at BATT+ was disconnected and then applied again without starting
up the TC65 module, the leakage current ranges between 90µA and 100µA.
If the TC65 module is started and afterwards powered down with AT^SMSO, then the
leakage current is only 50µA.
Therefore, in order to minimize the leakage current take care to start up the module at least
once before it is powered down.