Modes 3, 4, 5, And 6; Multiple Scales - Rice Lake IQ plus 800 Installation & Operation Manual

Digital weight indicator
Table of Contents

Advertisement

NOTE:
If you key in an ID number that
is already in memory, the
display reads "BAD ID" and
aborts the operation.
NOTE:
If keyed tares are enabled, the
tare weight need not be keyed
in, but can be obtained in the
normal manner from the weight
on the scale.
®
5-4
IQplus
800/810 Installation Manual
6. Key in the ID number (from the weigh-in ticket) and press PRINT.
The indicator prints the following weigh-out ticket and automati-
cally clears the information from memory:
ID. NO. 304812
GROSS
100000. LB
TARE
15000. LB RECALLED
NET
85000. LB
5/4/1994 10:55 AM
If it was a keyed tare, "KEYED" prints after "RECALLED" on the
tare line.

Modes 3, 4, 5, and 6

In these modes, the indicator stores the tare weights and ID numbers in
memory until you manually erase them.
1. The truck moves onto the scale for weigh-in.
2. Press TARE to store the scale weight. If keyed tares are enabled
(Modes 3, 5), you may instead key in the desired tare weight, then
press TARE.
3. Key in an ID number (up to 7 digits) and press NEW ID. This in-
formation remains in memory until manually deleted. Truck leaves.
4. The loaded truck moves back onto the scale for weigh-out.
5. Key in the ID number and press PRINT. The indicator prints the
weigh-out ticket. If value swapping is enabled (Modes 3, 4), the
lower weight will always be printed as the tare weight.

Multiple scales

If you use more than one scale with the truck in/out modes, the indicator
can print tickets indicating either an individual scale's total or a
combined total for all scales.
For an individual scale total, press SCALE # to select the scale before
printing a ticket. If more than one scale exists, the scale number also
appears on the ticket.
For a combined total of all scales, press SCALE # to select all active
scales before printing a ticket. "SCALE TOTAL" prints on the ticket
after the ID number.
ID. NO. 304812
GROSS
100000. LB
TARE
15000. LB RECALLED
NET
85000. LB
5/4/1994 10:55 AM
If you are using only a single scale setup on channel 1, either no scale
number, or SCALE # 1 will appear on the ticket.
SCALE TOTAL