Rice Lake IQ plus 800 Installation & Operation Manual page 114

Digital weight indicator
Table of Contents

Advertisement

:
NOTE
Two EDP commands, START
and END, change the START
and END concurrent setpoints,
respectively.
SETPNTS
RECIPE1
SETPT 1
GROSSSP
8-34
IQ plus 800/810 Installation Manual
EDP COMMANDS FOR MOVING RECIPES:
RECIPE
RECIPESAVE
RECIPERECALL Copies the recipe designated by RECIPE command into
RECIPEDUMP
CONCUR setpoint use in recipe storage option:
The recipe storage option uses a setpoint, called CONCUR, which can keep
a digital output active over the duration of several setpoints. The following
parameters apply to concurrent setpoints: VALUE, START, END, and
DIGOUT.
CONCURRENT SETPOINT TYPES:
Type 1:
Type 2:
If the VALUE parameter is greater than 0, then the Type 2 concurrent
setpoint is implemented. Otherwise, Type 1 is implemented. The maximum
number of Type 2 concurrent setpoints is five.
–GROSS
–NET
Corresponds to the recipe number affected by
RECIPESAVE and RECIPERECALL commands
Copies the working recipe into the recipe previously
selected with the RECIPE command
the working recipe
Sends all setpoint parameter settings for the current
working recipe to the EDP port. (Similar to DUMPALL,
but dumps only the setpoint parameters)
The digital output becomes active at the beginning of the
START setpoint and returns to an inactive state at the
beginning of the END setpoint.
The digital output becomes active at the beginning of the
START setpoint and returns to an inactive state after
VALUE (in 10ths of seconds).
CONCUR
BATCHPR
VALUE
START
Enter value
Scroll to
with keybd.
value
END
DIGOUT
Scroll to
Scroll to
value
value

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq plus 810Iq plus 810 dtIq plus 810 ssIq plus 810 he

Table of Contents