Rice Lake IQ plus 800 Installation & Operation Manual page 15

Digital weight indicator
Table of Contents

Advertisement

IQ plus 810 DT wiring: top view
The IQ plus 800 board locations
are the same for wiring purposes
®
2-4
IQ plus
800/810 Installation Manual
Figure 2-4.
LOAD CELL
DIGITAL I/O
CABLE TO J10
CABLE TO J4
J10
J10-1 +Sig
J10-2 -Sig
J10-3 +Sense
J10-4 -Sense
J10-5
Shield
3
J10-6 +Exc
J10-7 -Exc
SERIAL COMMUNICATIONS
CABLE TO J7
GROUND
SETUP SWITCH
7
6
5
4
3
2
Load Cell Wiring
J10
3-WIRE SUPPLY LINE REQUIRED
AC POWER
J7
1