Figure 8-31`. Panel mounting layout
(front view)
Figure 8-32. Panel mounting wiring
(side view)
TO J10
TO J7
TO J4
GROUND
IQ PLUS 810 PANEL MOUNT KIT (OPTIONAL)
The panel mounting kit for the IQ plus 810 Desktop model contains five
screws with washers which replace the original screws holding the body to
the faceplate. A template constructed from the drawing below may be used
to mark the hole cutout in the panel. See Figures 8-31 and 8-32.
1. Unplug the AC power cord before beginning.
2. Remove the back of the indicator by unscrewing the six machine bolts
holding the back to the faceplate.
3. Temporarily remove any cable connections from the indicator terminals.
Remove the ground cable from the cast lug on the rear of the indicator
case.
4. Using a template made from the drawing, transfer the cutout to the panel.
Cut out the panel and drill the holes to size.
5. Hold the faceplate against the panel as shown and secure with the five
machine screws and washers provided.
LOAD CELL
CABLE
6. Attach the ground wire that was connected to the lug on the indicator
body to one of the five screws.
7. Reattach cables to indicator terminals. Power up and test the indicator.
COMMUNICATIONS
CABLE
AC POWER CABLE
9-7/16
5
9/16
1/8 R (8) OPTIONAL
2-5/8
4
9-1/4
10
7/32 DIA. THRU (5)
Optional features
8-29