NOTE:
An access number is provided
when this option is purchased.
The option is enabled by
entering the access number
under the FEATURE submenu.
See the Configuration section
for more information.
NOTE:
The setpoint password cannot be
changed from the setpoint
submenu.
8-8
IQ plus 800/810 Installation Manual
PASSWORDS (OPTIONAL)
The password feature supports two passwords: one for the entire configura-
tion menu in setup mode and one for setpoint configuration from the
supervisor switch and from the SET POINT key.

Entering passwords

The passwords can be entered as parameters under the first level menu
CONFIG (from the submenu PASSWORD) if the password feature is
turned ON. The indicator reads PASSWORD. Move down in the menu
and the indicator will read CFG PWD for the CONFIG password and
SP PWD for the setpoint password. Move down again and enter up to
seven digits for each password. This is the only place either password
can be entered/changed.
CONFIG password: When you are in normal operating mode and
switch the CONFIG switch, the indicator will prompt CONF ID. You
can then enter the numeric password. As each digit is entered a "*" will
appear from left to right on the indicator. You must then press the
ENTER key. If the password is incorrect, the indicator will display
REJECT and return to the CONF ID prompt. There is no penalty for
entering an incorrect password. You can attempt to enter the password
as many times as you wish. Once a correct password is entered, the
indicator displays ACCEPT and then moves into the CONFIG menu.
SETPOINT password: The setpoint password works the same as the
CONFIG password. When you press the SET POINT key or enter
supervisor mode, the indicator will prompt STPT ID. You then enter the
numeric setpoint password and press ENTER. If incorrect REJECT will
appear and then STPT ID again. If correct, you can continue to view
alter the setpoint parameters. The setpoint password cannot be changed
from the setpoint submenu.

Disabling Passwords

Either or both of the CONFIG or SETPOINT passwords can be disabled
by entering a 0 (zero) for the password in the CONFIG menu. Because
passwords are saved on the EEPROM, the loss of battery backup will
not disable the passwords.

Backdoor password

If you forget the CONFIG password and have no way to enter the
CONFIG menu, call Rice Lake Weighing Systems. We can help you
find a unique "back-door" password to enter the CONFIG menu.