Keyboard Functions And Displays - Rice Lake IQ plus 800 Installation & Operation Manual

Digital weight indicator
Table of Contents

Advertisement

1
2
3
4
5
6
7
8
9
0
ENTER
ZERO
G/N
TARE
T
T
E
UNITS
PRINT

Keyboard functions and displays

The items in Table 1-4 describe various keys and display functions.
Table 1-4.
Numeric keypad
These keys let you enter numerical data. Normally, you key a number,
and then press ENTER and/or a function key. Each digit appears on the
display screen as entered. If you key a number and don't press ENTER
and/or a function key within several seconds, the display reverts to the
previous mode and the number is ignored.
If you make a mistake entering a number, press CLEAR to erase a
single digit. Continue pressing CLEAR to erase the remaining digits as
necessary.
If you key a number and press G/N before pressing ENTER, the number
is erased and the display reverts to the previous mode.
Zero
Eliminates weight from the display (when in Gross mode). This key will
not function when the scale is in motion, displaying Net weight, or
beyond the selected zero range.
G/N
Toggles between Gross and Net display modes. In Net mode, the display
shows net weight and the "N" annunciator lights. In Gross mode, the
display shows gross weight and the "G" annunciator lights.
Also, you can use G/N to revert to normal weighing mode if in another
mode.
Tare
Zeroes the displayed weight and places it into the tare register. The scale
must not be in motion, as indicated by:
If you press TARE in Gross mode, the indicator automatically changes
to Net mode and tares the current gross weight. If you type in a value
using the keypad, then press TARE, the indicator tares that value.
The T and rhombus appear on the display when a tare is in the system.
The TE and rhombus indicate a manually entered tare.
Units
Toggles the display between the primary and secondary units. Although
the standard label shows pounds and kilograms, other units can be
defined in the configuration menus.
Print
Prints a ticket when pressed in Normal Weighing Mode. You can
configure PRINT to operate in one of three modes: as a simple print
button (normal weighing mode), as a revolving-terminal data entry key
(Truck In/Out Mode 1), or as a fixed-terminal data entry key (Truck In/
Out Mode 2). In all cases, PRINT only functions when the scale is at
standstill
. Also, you can customize the ticket format (see
Custom Print Formatting Procedure in Section 9, Appendix).